Square D™ TeSys™ D LC1D25M7 Non-Reversing IEC Contactor With Protective Cover, 220 VAC V Coil, 25 A, 1NC-1NO Contact, 3 Poles - 35272

NEMA & IEC Contactors
35272 MFG #: LC1D25M7
0.00000 / each

Square D™ TeSys™ D IEC Contactor, Non-Reversing, Series: LC1D, 220 VAC Coil, 25 A Maximum Load Current, 20 hp Coil, 3 Pole, 50/60 Hz Frequency, 3.2/1.25 W Wattage, 1NC-1NO Contact Configuration, 25 A at 440 VAC Contact, Screw Clamp Terminal, Open Enclosure, 15000000 Cycles Operating Cycles, -20 to 60 deg C Operating, Surface Mounting, 3.35 in H x 1.77 in W x 3.62 in D Dimensions
QTY
  • Features
  • 6 kV conforming to IEC 60947 rated impulse withstand voltage
  • Overvoltage category III
  • 40 A at <=140 deg F power circuit/10 A at <=140 deg F signaling circuit conventional free air thermal current
  • 450 A at 440 VAC power circuit conforming to IEC 60947/140 A AC signaling circuit conforming to IEC 60947-5-1/250 A DC signaling circuit conforming to IEC 60947-5-1 IRMS rated making capacity
  • 450 A at 440 VAC power circuit conforming to IEC 60947 rated breaking capacity
  • 120 A <=104 deg F 1 min power circuit/240 A <=104 deg F 10 sec power circuit/380 A <=104 deg F 1 sec power circuit/50 A <=104 deg F (40 deg C) 10 min power circuit/100 A 1 s signaling circuit/120 A 500 ms signaling circuit/140 A 100 ms signaling circuit rated short time withstand current
  • 40 A gG at <=690 VAC coordination type 2 power circuit/63 A gG at <=690 VAC coordination type 1 power circuit/10 A gG signaling circuit conforming to IEC 60947-5-1 associated fuse rating
  • 2 mOhm at 50 Hz - Ith 25 A power circuit average impedance
  • 600 VAC power circuit certifications CSA/600 VAC power circuit certifications UL/690 VAC power circuit conforming to IEC 60947-4-1/690 VAC signaling circuit conforming to IEC 60947-1/600 VAC signaling circuit certifications CSA/600 VAC signaling circuit certifications UL rated insulation voltage
  • 12 to 22 ms closing/4 to 19 ms opening operating time
  • B10d is equal to 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1/B10d is equal to 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 safety reliability level
  • 3600 cycles/hr at <=140 deg F operating rate
  • Without built-in suppressor module coil technology
  • 2 to 3 W heat dissipation
  • 70 VA at 68 deg F (20 deg C) (cos 0.75) 50/60 Hz inrush power rating
  • 7.5 VA at 68 deg F (20 deg C) (cos 0.3) 60 Hz/7 VA at 68 deg F (20 deg C) (cos 0.3) 50 Hz hold in power consumption
  • 25 to 400 Hz signaling circuit frequency
  • 5 mA signaling circuit minimum switching current
  • 17 V signaling circuit minimum switching voltage
  • 1.5 ms on energisation between NC and NO contact/1.5 ms on de-energisation between NC and NO contact non-overlap time